维普中文期刊产品整合服务
5篇 您的检索式:作者名="Yinglin Ma"
    题名 作者 年代 出处 被引量
1A SKELETONIZATION ALGORITHM BASED ON EUCLIDEAN DISTANCE MAPS AND MORPHOLOGICAL OPERATORS显示文摘In this letter a new skeletonization algorithm is proposed. It combines techniques of fast construction of Euclidean Distance Maps(EDMs), ridge extraction, Hit-or-Miss Transformation(HMT) of structuring elements and the set operators. It first produces the EDM image with no more than 4 passes through an image of any kinds, and then the ridge image is extracted by applying a turn-on scheme and performing a rain-fall elimination to accelerate the processing. The one-pixel wide skeleton is finally acquired by carrying out the HMTs of two structure elements and the SUBTRACT and OR operations. Experimental results obtained by practical applications are also presented.Ma Lihong Yu Yinglin(Dept. of Electron. Eng. and Comm., South China Univ. of Tech. Guangzhou, 510641)Zhang Yu(Research Inst. of Computer Application, South China Univ. of Tech. Guangzhou, 510641) 2001Journal of Electronics(China)2001,18,3:3
2Development of a Label-Free Colorimetric Aptasensor with Rationally Utilized Aptamer for Rapid Detection of Okadaic Acid显示文摘Okadaic acid(OA)is a typical marine toxin with strong toxicity causing diarrheic shellfish poisoning(DSP).Aptamers show great advantages in toxin detection and attract increasing attentions in the field of food analysis.In this study,a label-free col-orimetric aptasensor was constructed for visual and rapid detection of OA in shellfish.To exploit the binding capability of the anti-OA aptamer,the inherent molecular recognition mechanism of aptamer and OA was studied,based on molecular docking,fluorescent assay,and biolayer interferometry.Consistent results showed that the stem-loop near the 3’terminal of the aptamer exhibit dominate binding capacity.Based on the revealed recognition information,the aptamer was thus rationally utilized and combined with AuNPs and cationic polymer polydiallyl dimethyl ammonium chloride(PDDA)for the development of the label-free colorimetric aptasensor,in which the 3’terminal was thoroughly exposed to OA.The aptasensor provided robust performance with a linear detection range of 100-1200 nmol L-1,a limit of detection of 41.30 nmol L-1,recovery rates of 91.6%-106.2%,as well as a high selectivity towards OA in shellfish samples.The whole detection process can be completed within 1 h.To our best knowledge,this is the first time that the anti-OA aptamer was thoroughly studied,and a label-free colorimetric aptasensor was rationally designed in this way.This study not only provides a rapid detection method for highly sensitive and specific detection of OA,but also serves as a reference for the design of efficient aptasensors in the future.YAN Xiaochen QI Xiaoyan ZHAO Yinglin LI Ling MA Rui WANG Lele WANG Sai MAO Xiangzhao 2022Journal of Ocean University of China2022,21,2:2
3The C_(6)D_(6)detector system on the Back-n beam line of CSNS显示文摘Introduction The neutron capture cross sections are very important in the field of nuclear device design and basic physics research.Hydrogen-free liquid scintillator such as C_(6)D_(6)detectors are widely used in the neutron capture cross-sectional measurements for the low neutron sensitivity and fast time response.The Back-n white neutron source at China Spallation Neutron Source is the first spallation white neutron source in China,and it is suitable for neutron capture cross-sectional measurement.Materials and methods A C_(6)D_(6)detector system was built in the Back-n experimental station.The pulse height weighting technique was used to determine the system’s detection efficiency.The response to gamma rays of the C_(6)D_(6)detector was measured,and the energy resolution function was determined.Monte Carlo simulation with Geant4 code was carried out to get the weighting function of this C_(6)D_(6)detector system.Additionally,the systematic uncertainty of the weighting function was also determined.Conclusion According to the experimental and simulation results,this C_(6)D_(6)detector system can be used to measure neutron capture cross section.Jie Ren Xichao Ruan Jie Bao Guangyuan Luan Wei Jiang Qi An Huaiyong Bai Ping Cao Qiping Chen Yonghao Chen Pinjing Cheng Zengqi Cui Ruirui Fan Changqing Feng Minhao Gu Fengqin Guo Changcai Han Zijie Han Guozhu He Yongcheng He Yuefeng He Hanxiong Huang Weiling Huang Xiru Huang Xiaolu Ji Xuyang Ji Haoyu Jiang Hantao Jing Ling Kang Mingtao Kang Bo Li Lun Li Qiang Li Xiao Li Yang Li Yang Li Rong Liu Shubin Liu Xingyan Liu Yinglin Ma Changjun Ning Binbin Qi Zhaohui Song Hong Sun Xiaoyang Sun Zhijia Sun Zhixin Tan Hongqing Tang Jingyu Tang Pengcheng Wang Qi Wang Taofeng Wang Yanfeng Wang Zhaohui Wang Zheng Wang Jie Wen Zhongwei Wen Qingbiao Wu Xiaoguang Wu Xuan Wu Likun Xie Yiwei Yang Han Yi Li Yu Tao Yu Yongji Yu Guohui Zhang Jing Zhang Linhao Zhang Liying Zhang Qingmin Zhang Qiwei Zhang Xianpeng Zhang Yuliang Zhang Zhiyong Zhang Yingtan Zhao Liang Zhou Zuying Zhou Danyang Zhu Kejun Zhu Peng Zhu 2019Radiation Detection Technology and Methods2019,3,3:1
4Role of oxygen-containing groups on MWCNTs in enhanced separation and permeability performance for PVDF hybrid ultrafiltration membranes显示文摘Jilan Ma Yufen Zhao Zhiwei Xu Chunying Min Baoming Zhou Yinglin Li Baodong Li Jiarong Niu 2013Desalination2013,,:1
5A Label-Free Colorimetric Aptasensor Containing DNA Triplex Molecular Switch and AuNP Nanozyme for Highly Sensitive Detection of Saxitoxin显示文摘Saxitoxin(STX),one of the most toxic paralytic shellfish poisons discovered to date,is listed as a required item of aquatic product safety inspection worldwide.However,conventional detection methods for STX are limited by various issues,such as low sensitivity,complicated operations,and ethical considerations.In this study,an aptamer-triplex molecular switch(APT-TMS)and gold nanoparticle(AuNP)nanozyme were combined to develop a label-free colorimetric aptasensor for the rapid and highly sensitive de-tection of STX.An anti-STX aptamer designed with pyrimidine arms and a purine chain was fabricated to form an APT-TMS.Specific binding between the aptamer and STX triggered the opening of the switch,which causes the purine chains to adsorb onto the surface of the AuNPs and enhances the peroxidase-like activity of the AuNP nanozyme toward 3,3’,5,5’-tetramethylbenzidine.Under optimized conditions,the proposed aptasensor showed high sensitivity and selectivity for STX,with a limit of detection of 335.6 pmol L^(−1) and a linear range of 0.59-150 nmol L^(−1).Moreover,good recoveries of 82.70%-92.66%for shellfish and 88.97%-106.5%for seawater were obtained.The analysis could be completed within 1 h.The proposed design also offers a robust strategy to achieve detection of other marine toxin targets by altering the corresponding aptamers.QI Xiaoyan LI Ling YAN Xiaochen ZHAO Yinglin WANG Lele MA Rui WANG Sai MAO Xiangzhao 2022Journal of Ocean University of China2022,21,5:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费