题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | Beam Phase Measurement System in SSC显示文摘The beam phase measurement is a key for obtaining an optimization of isochronous magnetic field in accelerator, to improve the beam quality and increase the beam intensity and efficiency of the beam extracted from accelerator. The 15 sets of the capacitive pick-up pha.se probes were mounted at equal distances above and below the median plane of the SSC.The size of the plate is 100×100 mm and the distance between two plates is 40 mm. The high frequency mixer and filter technology is used to develop the | Zheng Jianhua, Wang Yanmou, Ying Yan,Ma Weinian, Song Haihong and Liu Wei | 2005 | 近代物理研究所和兰州重离子加速器实验室年报:英文版2005,,1: | 0 |
| 2 | Elementary Application of Schottky Probe in CSRm Commissioning显示文摘Schottky signal analysis plays an important role in the HIRFL-CSR beam diagnostic system. The beam dynamic characteristic in the cooling storage ring is measured with the schottky probes. The relative momentum spreadΔp/p of the beam, the value of the tune Q, the revolution frequency of particles along the ring circumference and particle number can be acquired by the Schottky signal. Two Schottky | Zheng Jianhua, Xiao Guoqing, Mao Ruishi, Zhao Tiecheng, Wang Yanmou Ying Yan, Ma Weinian, Song Haihong and Wu Junxia | 2005 | 近代物理研究所和兰州重离子加速器实验室年报:英文版2005,,1: | 0 |
| 3 | Low Beam Current Measurement System显示文摘An intelligent instrument for low beam current measurement based on the microprocessor MSC1210 has been developed for the Faraday cups in the HIRFL-CSR beam diagnostic system. The system consists of the data acquisition, data analysis, and data display. The low beam current from FC is measured automatically by the system through signal acquisition, signal transformation, signal amplification, pulse signal shape rectification, A/D conversion, data treatment and result display. The structure diagram of the low beam current measurement system is shown in Fig. 1. | Yin Yan, Song Haihong, Xiao Guoqing,Zheng Jianhua,Ma Weinian and Wang Yanmou | 2005 | 近代物理研究所和兰州重离子加速器实验室年报:英文版2005,,1: | 0 |
| 4 | Development of Stepping Motor Controller for Beam Diagnostic System显示文摘Two kinds of movement mode are used for the beam diagnostic probe drive, one is driven by the compressed air and another is driven by the stepping motor. The slits are important for the beam tuning and physics experiments which are used to limit the beam. More than ten sets of slits are installed along the ECRS to CSRm beam transport line. The stepping motor controller for slits and other beam diagnostic probes is developed based on the microprocessor AT89C51. Fig. 1 shows the structure of stepping motor for the beam diagnostic system. | Wang Yanmou, Zheng Jianhua, Xiao guoqing,Ma Weinian, Ying Yan and Song Haihong | 2005 | 近代物理研究所和兰州重离子加速器实验室年报:英文版2005,,1: | 0 |
| 5 | Development of Embedded Controller for Video Switch显示文摘The fluorescent probe for beam profile measurement has been mostly used in HIRFL-CSR beam diagnostic system. Front controller for video switch is very important to send more than tens set of CCD signal coming from fluorescent probe to one set of display located in center control room, a new kind of embedded controller for video switch has been developed by ourselves. The diagram of embedded controller for video switch is shown as Figl. | Zheng Jianhua, Wang Yanmou, Ying Yan and Ma Weinian | 2003 | 近代物理研究所和兰州重离子加速器实验室年报:英文版2003,,1: | 0 |
| 6 | Transverse Emittance Measurement for the HIMM Cyclotron显示文摘The Heavy Ion Medical machine(HIMM)developed by the Institute of Modern Physics is now on its operation phase.The transverse emittance of the extracted beam from the HIMM cyclotron is measured and then optimized for injection into the synchrotron. | Feng Yongchun Li Min Mao Ruishi Wang Bing Li Shengpeng Li Weilong Ma Weinian Kang Xincai Zhang Jinquan Zhao Tiecheng Xu Zhiguo Zhao Zulong Wei Kun Yin Yan Chen Yucong Li Juan Ding Jiajian You Yaoyao Liu Tong Wang Yanmou Song Haihong Yuan Youjin | 2019 | IMP & HIRFL Annual Report2019,,1: | 0 |
| 7 | 电子束探针模拟和初步测试显示文摘Electron beam probe(EBP)is a non-interceptive device for beam profile measurement,which is under heavy development at many accelerator laboratories worldwide,i.e.SNS,FNAL,BINP,etc.,since the principle using charged particles as a probe beam to determine charge distribution is raised since the 1970s[1].EBP is especially suitable for high power accelerators because of its non-interceptability,and mainly devoted to circular machine.An EBP uses the deflection of a low energy electron beam in the target beam electromagnetic field to infer the profile information of the target beam.Measuring the deflection angle as a function of different impacts,one can reconstruct the beam distribution in the x or y direction. | Feng Yongchun Mao Ruishi Yin Yan Chen Yucong Dong Xiaoxia Li Juan Ding Jiajian You Yaoyao Liu Tong Kang Xincai Wang Yanmou Ma Weinian Song Haihong Li Weilong Xu Zhiguo Zhao Tiecheng | 2017 | IMP & HIRFL Annual Report2017,,1: | 0 |