|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | Risk factors for bleeding after endoscopic submucosal dissection of colorectal neoplasms显示文摘AIM:To investigate the risk factors for delayed bleeding following endoscopic submucosal dissection(ESD)treatment for colorectal neoplasms.METHODS:We retrospectively reviewed the medical records of 317 consecutive patients with 325 lesions who underwent ESD for superficial colorectal neoplasms at our hospital from January 2009 to June2013.Delayed post-ESD bleeding was defined as bleeding that resulted in overt hematochezia 6 h to 30d after ESD and the observation of bleeding spots as confirmed by repeat colonoscopy or a required blood transfusion.We analyzed the relationship between risk factors for delayed bleeding following ESD and the following factors using univariate and multivariate analyses:age,gender,presence of comorbidities,use of antithrombotic drugs,use of intravenous heparin,resected specimen size,lesion size,lesion location,lesion morphology,lesion histology,the device used,procedure time,and the presence of significant bleeding during ESD.RESULTS:Delayed post-ESD bleeding was found in14 lesions from 14 patients(4.3%of all specimens,4.4%patients).Patients with episodes of delayed postESD bleeding had a mean hemoglobin decrease of2.35 g/dL.All episodes were treated successfully using endoscopic hemostatic clips.Emergency surgery was not required in any of the cases.Blood transfusion was needed in 1 patient(0.3%).Univariate analysis revealed that lesions located in the cecum(P=0.012)and the presence of significant bleeding during ESD(P=0.024)were significantly associated with delayed post-ESD bleeding.The risk of delayed bleeding was higher for larger lesion sizes,but this trend was not statistically significant.Multivariate analysis revealed that lesions located in the cecum(OR=7.26,95%CI:1.99-26.55,P=0.003)and the presence of significant bleeding during ESD(OR=16.41,95%CI:2.60-103.68,P=0.003)were independent risk factors for delayed post-ESD bleeding.CONCLUSION:Location in the cecum and significant bleeding during ESD predispose patients to delayed post-procedural bleeding.Therefore,careful and additional management is recommended for these patients. | Sho Suzuki Akiko Chino Teruhito Kishihara Naoyuki Uragami Yoshiro Tamegai Takanori Suganuma Junko Fujisaki Masaaki Matsuura Takao Itoi Takuji Gotoda Masahiro Igarashi Fuminori Moriyasu | 2014 | World Journal of Gastroenterology2014,20,7: | 21 |
| 2 | Prevalence and Risk Factors of Atrial Fibrillation in Chinese Elderly: Results from the Chinese Longitudinal Healthy Longevity Survey显示文摘 | Choy-Lye Chei Prassanna Raman Chi Keong Chino Zhao-Xue Yin Xiao-Ming Shi Yi Zeng David B Matchar | 2015 | Chinese Medical Journal2015,,18: | 7 |
| 3 | High strain rate superplasticity of rolled AZ91 magnesium alloy显示文摘The high strain rate superplastic deformation properties and characteristics of a rolled AZ91 magnesium alloy at temperatures ranging from 623 to 698 K(0.67Tm-0.76Tm) and high strain rates ranging from 10-3 to 1 s-1 were investigated.The rolled AZ91 magnesium alloy possesses excellent superplasticity with the maximum elongation of 455% at 623 K and a strain rate of 10-3 s-1,and its strain rate sensitivity m is high up to 0.64.The dominant deformation mechanism responsible for the high strain rate superplasticity is still grain boundary sliding(GBS),and the dislocation creep mechanism is considered as the main accommodation mechanism. | WANG Qudong WEI Yinhong Y. Chino M. Mabuchi | 2008 | Rare Metals2008,27,1: | 6 |
| 4 | Variation in Texture and Lankford Value of 1070 Aluminum Sheet Rolled by Cone-shaped Roll显示文摘A rolling with cone-shaped roll, the diameter of which continuously varies along the axial direction, has been proposed as a new shear rolling for controlling the texture of an aluminum alloy sheet. In this study, variations in the texture and Lankford value of a 1070 aluminum sheet rolled by the cone-shaped roll were investigated. Rolling with the cone-shaped roll was found to impose intense shear strain at the edges of the specimen, specifically near the surface. The shear directions in the left and right portions of the specimen were opposite to each other. The surface and middle layer of the specimen rolled by the cone-shaped roll and the reference specimen were characterized by a shear texture and typical recrystallization texture components, respectively. Notably, the specimen rolled by the cone-shaped roll exhibited smaller texture intensity than the reference specimen, especially at the surface, and the shear texture-components were observed at relatively deeper positions. As a result of Lankford value measurements, the specimen rolled with the cone-shape roll exhibited a smaller planar anisotropy than the reference specimen and an average Lankford value close to unity, which are likely due to the texture modifications introduced during rolling with the cone-shaped roll. | Yasumasa Chino Xinsheng Huang Kazutaka Suzuki Mamoru Mabuchi | 2013 | Journal of Materials Science & Technology2013,29,2: | 2 |
| 5 | Treatment strategy for rectal carcinoids: A clinicopathological analysis of 229 cases at a single cancer institution显示文摘 | Akiyoshi Kasuga Akiko Chino Naoyuki Uragami Teruhito Kishihara Masahiro Igarashi Rikiya Fujita Noriko Yamamoto Masashi Ueno Masatoshi Oya Tetsuichiro Muto | 2012 | Journal of Gastroenterology and Hepatology2012,,12: | 2 |
| 6 | SGLT2 inhibitor lowers serum uric acid through alteration of uric acid transport activity in renal tubule by increased glycosuria显示文摘 | Yukihiro Chino Yoshishige Samukawa Soichi Sakai Yasuhiro Nakai Jun‐ichi Yamaguchi Takeo Nakanishi Ikumi Tamai | 2014 | Biopharm. Drug Dispos2014,,: | 2 |
| 7 | 广色域移动显示产品开发显示文摘当移动电话、PDA等电子产品迅速涌入市场,宽色域将成为应用于相同领域的下一代LCD的要求。本文介绍了一种可用于移动电子产品的四基色宽色域技术。 | Eiji Chino 刘金权(译) 潘良玉(译) | 2007 | 现代显示2007,,8: | 2 |
| 8 | Novel equilibrium two phase Mg alloy with the long-period ordered structure显示文摘 | Yasumasa Chino Mamoru Mabuchi Shigehiro Hagiwara Hajime Iwasaki Atsushi Yamamoto Harushige Tsubakino | 2004 | Scripta Materialia2004,,7: | 2 |
| 9 | Clinical characterization of gastric lesions initially diagnosed as low‐grade adenomas on forceps biopsy显示文摘 | Akiyoshi Kasuga Yorimasa Yamamoto Junko Fujisaki Kazuhisa Okada Masami Omae Akiyoshi Ishiyama Toshiaki Hirasawa Akiko Chino Tomohiro Tsuchida Masahiro Igarashi Etsuo Hoshino Noriko Yamamoto Minoru Kawaguchi Rikiya Fujita | 2012 | Digestive Endoscopy2012,,5: | 2 |
| 10 | Long-term outcomes of endoscopic submucosal dissection for undifferentiated-type early gastric cancer显示文摘 | K. Okada J. Fujisaki T. Yoshida H. Ishikawa T. Suganuma A. Kasuga M. Omae M. Kubota A. Ishiyama T. Hirasawa A. Chino M. Inamori Y. Yamamoto N. Yamamoto T. Tsuchida Y. Tamegai A. Nakajima E. Hoshino M. Igarashi | 2012 | Endoscopy2012,,02: | 2 |
| 11 | Uniformly sized molecularly imprinted polymer for d-chlorpheniramine evaluation of retention and molecular recognition properties in an aqueous mobile phase 显示文摘 | Haginaka Jun Kagawa Chino | 2002 | Z of Chromatography A2002,948,: | 1 |
| 12 | Identification and behavior of reaction products formed by chlorination of ethynylestradiol显示文摘 | Moriyama K Matsufuji H Chino M | 2004 | Chemosphere2004,55,6: | 1 |
| 13 | Clinic pathological studies of esophageal carcinoma in achalasia:analyses of carcinogenesis using histological and immunohistochemical procedures 显示文摘 | Chino O Kijima H Shimada H | 2000 | Anticancer REs2000,20,5: | 1 |
| 14 | Processing of biocompatible porous Ti and Mg显示文摘 | WEN C E MABUCHI M YAMADA Y SHIMOJIMA K CHINO Y ASAHINA T | 2001 | Scripta Materialia2001,45,10: | 1 |
| 15 | Processing and mechanical properties of autogenous titanium implant materials 显示文摘 | WEN C E YAMADA ~ SHIMOJIMA K CHINO Y ASAHINA T MABUCHI M | 2002 | Journal of Materials Science: Materials in Medicine2002,13,4: | 1 |
| 16 | Processing of biocompatible porous Ti and Mg显示文摘 | WEN CE MABUCHI M Yamanda Y SH1MOJIMA K CHINO Y ASAHINA T | 2001 | Scripta Materialia2001,45,10: | 1 |
| 17 | Processing of biocompatible porous Ti and Mg 显示文摘 | WEN C E MABUCHI M YAMADA Y SHIMOJIMA K CHINO Y ASAHINA T | 2001 | Scripta Materialia2001,45,10: | 1 |
| 18 | Preliminary of 131I and 137Cs accidentally discharged from the Fukushima Daiichi nuclear power plant into the atmosphere 显示文摘 | Chino M Nakayama H estimation of release amounts Nagai H | 2011 | Journal of Nuclear Science and Technology2011,48,7: | 1 |
| 19 | New technique of en bloc resection of colorectal tumor using laparoscopy and endoscopy cooperatively (laparoscopy and endoscopy cooperative surgery-colorectal) 显示文摘 | Fukunaga Y Tamegai Y Chino A | 2014 | Dis Colon Rectum2014,57,: | 1 |
| 20 | Tensile properties of directionally solidified AZ 91 Mg alloy 显示文摘 | Mabuchi M Kobata M Chino Y | 2003 | Materials Transactions2003,44,4: | 1 |